## Discrepancy

AT GATE INBD GOT VENT BLOWER FAULT. BLOWER FAN KICKED OFF AND THEN EICAS SHOWED AVIONICS SMOKE W/ACRID ELECTRICAL SMELL. RAN QRH AND THEN GEN1 LINE SMOKE LIGHT APPEARED QRH RAN AND GEN1 LINE DISCONNECTED; R&R VENT BLOWER FAN 20QH PER AMM 21-26-51. AEVC PER DUE NO TEST OF FANS PERFORMED OP TEST OF AEVC AND SMOKE. OPS TEST PASS.

---