# SDR DALA2026090104929

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 13, 2024
- Submitted: September 1, 2026
- Operation: Air carrier
- Aircraft: [N309DU](https://openairdocs.org/aircraft/N309DU), registered now
- Make and model: Airbus BD-500-1A11
- Registry model: [Airbus BD-500-1A11](https://openairdocs.org/model/airbus-canada-lp-bd-500-1a11) (OpenAirDocs)
- Aircraft serial: 55107
- Aircraft time: 15,604 hours, 6,844 cycles
- System (JASC): [5510 · Horizontal Stabilizer Structure](https://openairdocs.org/jasc/5510)
- Part: Erosion Shield
- Condition: Missing
- Location: Zone 300
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DALA2026090104929

## Discrepancy

RIGHT HORIZONTAL TIP FAIRING EROSION PROTECTIVE MATERIAL NOT INSTALLED.  APPLIED TIP FAIRING TEMP REPAIR IAW A220 AMP 55-12-86-01AAA- 662A-A. PERMANENT REPAIR REQUIRED AT 8500 FH. GVI TO BE PERFORMED EVERY 150 FH. FWD TO MON.   (LP# 6171230; AIRCRAFT WAS GROUNDED)

---