# SDR DALA2026092405345

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 17, 2026
- Submitted: September 25, 2026
- Operation: Air carrier
- Aircraft: [N129DU](https://openairdocs.org/aircraft/N129DU), registered now
- Make and model: Airbus BD-500-1A10
- Registry model: [Airbus BD-500-1A10](https://openairdocs.org/model/airbus-canada-ltd-ptnrsp-bd-500-1a10) (OpenAirDocs)
- Aircraft serial: 50048
- Aircraft time: 16,793 hours, 7,874 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Hose
- Condition: Leaking
- Location: Hyd Sys
- Stage of operation: CL
- How discovered: O
- Nature of condition: K, B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DALA2026092405345

## Discrepancy

DIRTY SOCK ODOR IN AFT GALLEY AFTER TAKEOFF, DIRTY SOCK ODOR IN COCKPIT DURING DECENT AND LANDING. CREW REPORTED ODOR ON DESCENT STARTED AT 9000 FT. PAX COMPLAINED OF ODOR AS WELL WIP362362. WHILE CHANGING BUFFER AIR SOV OF NR 1 ENG, FOUND FLUID LEAKING FROM HYD EDP PRESSURE HOSE AT BOTH END FITTINGS. REPLACED NR 1 ENG EDP HYD PRESSURE HOSE PER IAW AMP29-11-49. OPS & LEAK CHECKS GOOD. (LP# 7902245, 7902253: AIRCRAFT WAS GROUNDED)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.