# SDR DHL2002363003

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 16, 2002
- Submitted: April 19, 2002
- Operation: Air carrier
- Aircraft: [N363DH](https://openairdocs.org/aircraft/N363DH), registered now
- Make and model: Airbus A300 B4-203
- Registry model: [Airbus A300 B4-203](https://openairdocs.org/model/airbus-industrie-a300-b4-203) (OpenAirDocs)
- Aircraft serial: 85
- System (JASC): [2613 · Overheat Detection](https://openairdocs.org/jasc/2613)
- Part: Control Unit
- Part number: 3500813
- Part serial: UNK
- Stage of operation: IN
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DHL2002363003

## Discrepancy

1. MANIFOLD FAULT DETECT LOOPS RH SELECT B TEST FAILS.  2. DEFERRED PER MEL 36-12-03. CONTROL #9034 ASSIGNED. 3. REPLACED #2 OVERHEAT DETECTION CONTROL UNIT IAW M/M 26-16-11. OPS CK  GOOD. THIS CLEARS DMI 9034.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.