# SDR DHL2003807007

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 19, 2003
- Submitted: May 22, 2003
- Operation: Air carrier
- Aircraft: N807DH
- Make and model: Doug DC-8-73F
- Registry model: [Doug DC-8-73F](https://openairdocs.org/model/douglas-dc-8-73f) (OpenAirDocs)
- Aircraft serial: 45990
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Line
- Part number: 000AA5060324
- Condition: Leaking
- Location: Hyd System
- Stage of operation: CL
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DHL2003807007

## Discrepancy

AFTER T/O UPON GEAR RETRACTION HYD SYS PX WENT TO ZERO , HYD QTY WENT TO HALF FULL. AILERON CONTROL MANUAL LIGHT ILLUMINATED. COMPLETED HYD PX ABNORMAL. ABNORM PROCEDURE, PX DID NOT INCREASE HYD QTY DECREASED TO AUX LEVEL. COMPLETED HYD QTY LOSS ABNORMAL PROCEDURE, FLAPS WOULD  NOT EXTEND HYD PX DID NOT INCREASE, HYD QTY DROPPED TO JUST ABOVE EMER. LEVEL. COMPLETED HYD SYS FAILED EMERGENCY CHECKLIST AND LANDED BACK AT SDQ.   T/S SYSTEM FOUND FLEX HYD LINE BROKEN. R&R FLEX LINE IAW MM 29-10-0 ON LH BOGIE TRIM ACTUATOR. SERVICED MAIN HYD. SYSTEM I/A/W/ MM 12-30-1 AND  RAN NR 2 AND 3 ENGS I/A/W/ JRH. NO LEAKS NOTED. SYSTEM NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.