## Discrepancy

MANIFOLD NR 2 OVER TEMP ILLUMINATED IN FLIGHT, TEMP WAS 215 DEGREES CELSIUS, PERFORMED CHECK LIST AND LIGHT WENT OUT.  ENGINE DE-ICE WAS ON AT THE TIME.  OPENED PYLON, CHECKED DUCTING FOR SECURITY, FOUND OKAY.  PRE-COOLER VALVE FOR OPERATION WAS OKAY, REGULATING VALVE AND MUSCLE LINE OKAY, TEMP SENSOR MANIFOLD FOUND OKAY AND SECURED.  FOUND AIR LEAKAGE ON NR 2 ENGINE FIREWALL SHUT OFF VALVE, SECURED CLAMPS AND OPERATES OKAY.

---