# SDR DJFA20150317001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 17, 2015
- Submitted: March 26, 2015
- Operation: Air carrier
- Aircraft: N314FL
- Make and model: Emb EMB-505
- Registry model: [EMB EMB-505](https://openairdocs.org/model/embraer-executive-emb-505) (OpenAirDocs)
- Aircraft serial: 50500050
- Aircraft time: 3,556 hours, 2,309 cycles
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Power Supply
- Condition: Failed
- Location: Emergency Lights
- Stage of operation: CR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DJFA20150317001

## Discrepancy

DURING FLIGHT CREW NOTICED AN ELECTRICAL ODOR.  DIVERTED FLIGHT & DECLARED AN EMERGENCY.  FOUND THE NR 1 EMERGENCY LIGHT POWER SUPPLY BAD. OPS CHECKED PASSED.   BOTH EMER POWER SUPPLIES WERE REPLACED IAW SERVICE BULLETIN 33-0007.  ALSO REPLACED THREE EMERGENCY LIGHTS.  OPS CHECKED GOOD & THE ACFT RETURNED TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.