# SDR DJFA20160813001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 13, 2016
- Submitted: August 18, 2016
- Operation: Air carrier
- Aircraft: [N347FX](https://openairdocs.org/aircraft/N347FX), registered now
- Make and model: Emb EMB-505
- Registry model: [EMB EMB-505](https://openairdocs.org/model/embraer-executive-emb-505) (OpenAirDocs)
- Aircraft serial: 50500094
- Aircraft time: 1,933 hours, 1,397 cycles
- System (JASC): [3620 · Pneumatic Indicating System](https://openairdocs.org/jasc/3620)
- Part: Thermal Switch
- Condition: Defective
- Location: Bleed Air Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DJFA20160813001

## Discrepancy

DIVERTED DUE TO "BLEED 2 LEAK" CAS MESSAGE.  COMPLETED QRH PROCEDURE AND CAS MESSAGE CLEAR. DURING DECENT CAS MESSAGE CAME BACK. COMPLETED QRH PROCEDURES TO SECOND END POINT AND CAS MESSAGE CLEARED AND REMAINED OFF FOR REMAINDER OF FLIGHT.  CREW DECLARED AN EMERGENCY. LANDED WITHOUT INCIDENT.  REPLACED TWO BLEED LEAK THERMAL SWITCHES ON INBOARD AND OUTBOARD OF RT PYLON PRECOOLER.  OPS CHECK GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.