# SDR DL76G020317

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 16, 2002
- Submitted: April 3, 2002
- Operation: Air carrier
- Aircraft: [N1605](https://openairdocs.org/aircraft/N1605), registered now
- Make and model: Boeing 767332
- Aircraft serial: 30198
- Aircraft time: 13,589 hours, 2,207 cycles
- System (JASC): [2160 · Cabin Temperature Control System](https://openairdocs.org/jasc/2160)
- Part: Control Valve
- Part number: 3987505
- Part serial: 9061024
- Condition: Faulty
- Location: Air Conditioning
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DL76G020317

## Discrepancy

LT PACK TEMP OFF MULTIPLE TIMES BUT ALWAYS RESET.  LT AND RT TEMP CONTROL VALVES FAULTED.  REPLACED BOTH VALVES.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.