# SDR DL76G081483

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 31, 2008
- Submitted: November 18, 2008
- Operation: Air carrier
- Aircraft: N155DL
- Make and model: Boeing 767-3P6
- Registry model: [Boeing 767-3P6](https://openairdocs.org/model/boeing-767-3p6) (OpenAirDocs)
- Aircraft serial: 25269
- Aircraft time: 74,218 hours, 15,619 cycles
- System (JASC): [2330 · Entertainment System](https://openairdocs.org/jasc/2330)
- Part: Electrical Box
- Part number: PS45222252
- Condition: Overheated
- Location: 2 A/ 2b
- Stage of operation: CR
- How discovered: O
- Nature of condition: M, B
- Precautionary procedure: H
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DL76G081483

## Discrepancy

DUE TO FUMES THE IFE SYSTEM WAS SHUTDOWN.  REMOVED AND REPLACED DC SEB P/N RD-FA 3124-07.  REMOVED AND REPLACED SPM P/N RD-FA 3621-01 AND R SAC CONTROL BOX P/N PS4-52222-52.  ALL IFE AND SEAT FUNCTION OPS NORMAL AT 5 A/B.

---