# SDR DL76G990300

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 15, 1999
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N156DL
- Make and model: Boeing 767-3P6
- Registry model: [Boeing 767-3P6](https://openairdocs.org/model/boeing-767-3p6) (OpenAirDocs)
- Aircraft serial: 25354
- System (JASC): [3097 · Ice/Rain Protection System Wiring](https://openairdocs.org/jasc/3097)
- Part: Wire
- Condition: Shorted
- Location: Fwd Galley
- Stage of operation: CR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: H
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DL76G990300

## Discrepancy

ELECTRICAL ARC NOTED SEVERAL TIMES IN FORWARD GALLEY RT SIDE NEAR DRAIN SHUT-OFF VALVE.  FOUND FEEDER WIRE TO FWD GALLEY SUPPLY SIDE RIBBON     HEATER B109 SHORTED TO GALLEY STRUCTURE.  REPAIRED AND REROUTED WIRE, TRIM REINSTALLED IPC REF 30-71-02 PG 106 SHEET 1.

---