## Discrepancy

CREW REPORTS BLEED OFF ENG L MESSAGE RESET AND TRIPPED AGAIN APPROX 40 MINUTES LATER.  A/C RETURNING TO ATL FOUND MAINT MESSAGE 36-10500.  MANIFOLD DUAL TEMP SENSOR LEFT FAILED.  REPLACED SAME PER M/M.  RAN ENGINE TO POWER AND ALS PERFORMED ENGINE BLEED AIR OPERATIONAL TEST PER M/M.  NO MESSAGES.  OPS CK GOOD.  ETOPS CATEGORY 'B': DIVERSION OR TURNBACK.

---