# SDR DLM11991947

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 1, 1999
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N806DE](https://openairdocs.org/aircraft/N806DE), registered now
- Make and model: Doug MD-11
- Registry model: [Doug MD-11](https://openairdocs.org/model/mcdonnell-douglas-md-11) (OpenAirDocs)
- Aircraft serial: 48477
- System (JASC): [3840 · Air Supply (Water Pressure System)](https://openairdocs.org/jasc/3840)
- Part: Water Comp
- Condition: Failed
- Location: Nr 1
- Component: 8378M11
- Stage of operation: CR
- Nature of condition: B
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DLM11991947

## Discrepancy

PAX AT 3B NOTICED A HOT WIRE SMELL.  THE CREW ALSO NOTICED THE SMELL.  LATER F/A AND PASSENGER COMPLAINED OF HEADACHES INSPECTED CEILING FWD CABIN FOR BURNING WIRE CK OK.  CHECKED SIDEWALL OF FWD CRAGO COMP FOUND NR 1 WATER COMP BEARING FAILURE.  REPLACED NR 1 WATER COMP.  CKS GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.