# SDR DLM88020560

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 17, 2002
- Submitted: May 30, 2002
- Operation: Air carrier
- Aircraft: N938DL
- Make and model: Doug MD-88
- Registry model: [Doug MD-88](https://openairdocs.org/model/mcdonnell-douglas-md-88) (OpenAirDocs)
- Aircraft serial: 49811
- Aircraft time: 34,973 hours, 27,910 cycles
- Engine: Pwa JT8D219
- Engine time: 20,505 hours, 16,057 cycles
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Condition: Malfunctioned
- Location: Rt Engine
- Part time: 20,505 hours, 16,057 cycles
- Stage of operation: CL
- How discovered: O
- Nature of condition: H, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DLM88020560

## Discrepancy

DIVERSION, RT A/C SYSTEM BUS FAILURE.  COULD NOT PWR FROM OTHER SOURCES.  FOUND DISTURB FAULT ON GCU AND CROSSTIE LOCKOUT ON EOAP INSP GEN FEEDER CABLES FROM GEN TO TAIL SECTION, CKS OK.  MEGGED GEN CABLES, CKS OK.  REMOVED AND REPLACED NR 2 CTS, 3 EACH AND GEN AND GCU PER MM RAN ENG CKS OK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.