# SDR DLM88962599

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 27, 1996
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N954DL
- Make and model: Doug MD-88
- Registry model: [Doug MD-88](https://openairdocs.org/model/mcdonnell-douglas-md-88) (OpenAirDocs)
- Aircraft serial: 49885
- System (JASC): [2170 · Humidity Control System](https://openairdocs.org/jasc/2170)
- Part: Water Separator
- Part number: 21D101
- Condition: Dirty
- Location: Cabin
- Stage of operation: CL
- Nature of condition: B
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DLM88962599

## Discrepancy

F/A REPORTED, LAV SMOKE ALARM ON F/O SIDE WENT OFF AND WOULD NOT STOP.  SMELLED SMOKE LATER, REPORTED IT SMELLED ELECTRICAL.  INSPECTED RIGHT AFT LAV, NOTHING FOUND.  REPLACED SMOKE  DETECTOR, WATER SEPARATOR BAGS AND PERFORMED CROSS OVER DUCT BURNOUT PROCEDURE PER M/M 36-10-00 PG 507 TO 508, RAN PACKS AND ALL CHECKS OK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.