# SDR DLM90951824

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 27, 1995
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N902DA
- Make and model: Doug MD-90-30
- Registry model: [Doug MD-90-30](https://openairdocs.org/model/mcdonnell-douglas-md-90-30) (OpenAirDocs)
- Aircraft serial: 53382
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Part number: 28B5274
- Condition: Oil Leak
- Location: Nr 1/2 Engine
- Stage of operation: CR
- Nature of condition: H, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DLM90951824

## Discrepancy

DURING CRUISE, RT AS POWER FAULT ILLUMINATED ALONG WITH OIL PRESSURE FAULT.  STARTED APU, THEN LEFT GENERATOR AC POWER FAULT CAME ON WITH LEFT GENERATOR AND OIL PRESSURE STATUS LIGHT, THEN LEFT GENERATOR TRIPPED OFF LINE.  LANDED EWR, FOUND BOTH GENERATORS WITH LOW OIL, EVIDENCE OF LEAKAGE IN ENGINE COWL.  SERVICED GENERATORS AND FOUND LEFT GENERATOR FILTER BOWL HOUSING CRACKED AND THE RT GENERATOR PRESSURE SERVICING PORT LEAKING.  REPLACED BOTH GENERATORS.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.