# SDR DLM90960341

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 9, 1996
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N908DA
- Make and model: Doug MD-90-30
- Registry model: [Doug MD-90-30](https://openairdocs.org/model/mcdonnell-douglas-md-90-30) (OpenAirDocs)
- Aircraft serial: 53388
- System (JASC): [2410 · Alternator-Generator Drive](https://openairdocs.org/jasc/2410)
- Part: Filter Bowl
- Part number: 41320691
- Condition: Cracked
- Location: Rt Engine
- Stage of operation: CR
- Nature of condition: K
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DLM90960341

## Discrepancy

RIGHT AC FAULT CAME ON DURING CRUISE, ALONG WITH STATUS MSG RT GEN OIL PRESS.  STARTED APU AND PICKED UP RT AC LOAD.  THEN RTI GEN OFF ILLUMINATED.  FOUND RT VSCF GEN OIL LOW WITH FILTER HOUSING CRACKED AND LEAKING.  REPLACED FILTER BOWL. SERVICED, OPERATION NORMAL.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.