# SDR DXTA200702266

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 14, 2007
- Submitted: June 15, 2007
- Operation: Air carrier
- Aircraft: [N601QS](https://openairdocs.org/aircraft/N601QS), registered now
- Make and model: Cessna 560XL
- Registry model: [Cessna 560XL](https://openairdocs.org/model/cessna-560xl) (OpenAirDocs)
- Aircraft serial: 5605301
- Aircraft time: 4,666 hours, 3,601 cycles
- Engine: Pwa PW545A
- System (JASC): [2120 · Air Distribution System](https://openairdocs.org/jasc/2120)
- Part: Unknown
- Condition: Odor
- Location: Cabin
- Stage of operation: CL
- How discovered: O
- Nature of condition: B
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA200702266

## Discrepancy

AFTER TAKEOFF RECEIVED ACM OVERHEAT INDICATION WITH  RT BLEED AIR AND RT ITT (RED FLAG) INDICATION, ALSO HAD A ODOR OF SOMETHING BURNED COMING OUT OF THE VENTS ITT WAS APPROXIMATELY BETWEEN 750-760 DEG F FOR 4-5 SECONDS.  [07-09-07]  REMOVED AND REPLACED THE RT FLOW CONTROL VALVE W/A OVERHAULED UNIT AS PER THE CE560XL AMM CHAPTER 21-11-00. OPS CHECKS GOOD. LEAK CHECK SATISFACTORY

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.