# SDR DXTA200702588

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 1, 2007
- Submitted: November 9, 2007
- Operation: Air carrier
- Aircraft: N718QS
- Make and model: Gulstm 200
- Aircraft serial: 136
- Aircraft time: 1,240 hours, 759 cycles
- Engine: Pwc PW306A
- System (JASC): [2435 · Starter-Generator](https://openairdocs.org/jasc/2435)
- Part: Starter Gen
- Part number: 23291006
- Part serial: Y0036
- Condition: Inoperative
- Location: Rt Engine
- Part time: 950 hours, 571 cycles
- Stage of operation: TO
- How discovered: O
- Nature of condition: H
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA200702588

## Discrepancy

RT GENERATOR FAILED AFTER  TAKEOFF POWER , R/T GEN WOULD NOT STAY  RESET NOR HOLD AMP LOAD  NOR VOLTS, TO ABORTED.  REMOVED AND REPLACED RH STARTER GEN PER G200 MM 24-30-06. OPS CHECK GOOD PER G200 MM 24-30-00

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.