# SDR DXTA200809103272

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 10, 2008
- Submitted: May 20, 2009
- Operation: Air carrier
- Aircraft: [N318QS](https://openairdocs.org/aircraft/N318QS), registered now
- Make and model: Cessna 560CESSNA
- Aircraft serial: 5600418
- Aircraft time: 10,225 hours, 8,394 cycles
- System (JASC): [3040 · Windshield/Door Rain/Ice Removal](https://openairdocs.org/jasc/3040)
- Part: Control Valve
- Part number: 99120864
- Part serial: 3064ABCDEG
- Condition: Inoperative
- Location: Windshield Heat
- Stage of operation: TO
- How discovered: O
- Nature of condition: J
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA200809103272

## Discrepancy

DURING TAKEOFF ROLL AT 50 KNOTS W/S AIR O-HEAT ANNUNCIATOR LIGHT ILLUMINATED, PERFORMED ABORT.  WHEN POWER WAS REDUCED LIGHT WENT OUT.   REMOVED WINDSHIELD BLEED AIR CONTROL VALVES DUE TO "OVERHEAT" ON TAKE OFF. INSTALLED OVERHAULED VALVE IAW MM 30-41-00, OPS CHECKED AND LEAK CHECKED GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.