# SDR DXTA200906043678

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 4, 2009
- Submitted: June 5, 2009
- Operation: Air carrier
- Aircraft: [N587QS](https://openairdocs.org/aircraft/N587QS), registered now
- Make and model: Cessna 560XL
- Registry model: [Cessna 560XL](https://openairdocs.org/model/cessna-560xl) (OpenAirDocs)
- Aircraft serial: 5605805
- Aircraft time: 604 hours, 457 cycles
- System (JASC): [2740 · Stabilizer Control System](https://openairdocs.org/jasc/2740)
- Part: Actuator
- Part number: 41011680108
- Part serial: 0757
- Condition: Bypassing
- Part time: 457 cycles
- Stage of operation: CL
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA200906043678

## Discrepancy

STAB MISCOMPARE ILLUMINATED AFTER TAKOFF, RAN CHECKLIST AND LIGHT WENT OUT AFTER THE HYD CONTROL C/B WAS CYCLED.  FOUND HORIZ STAB ACTUATOR BYPASSING HYDRO FLUID.  REMOVED AND REPLACED STAB ACTUATOR.  LEAK AND OPS CHECK GOOD. IAW MM 27-40-00.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.