# SDR DXTA2011030804496

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 6, 2011
- Submitted: March 8, 2011
- Operation: Air carrier
- Aircraft: [N930QS](https://openairdocs.org/aircraft/N930QS), registered now
- Make and model: Cessna 750
- Registry model: [Cessna 750](https://openairdocs.org/model/cessna-750) (OpenAirDocs)
- Aircraft serial: 7500130
- Aircraft time: 9,188 hours, 5,626 cycles
- System (JASC): [3030 · Pitot/Static Anti-Ice System](https://openairdocs.org/jasc/3030)
- Part: Circuit Breaker
- Part number: S2899L75
- Condition: Failed
- Location: Pitot
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA2011030804496

## Discrepancy

AMBER CAS L STATIC HEAT FAIL. ALSO L PITOT HEAT FAIL.  RESET CIRCUIT BREAKER.  OPS CHECKED GOOD ON GROUND.  REMOVED LT CIRCUIT BREAKER PANEL.  OHMED THROUGH PITOT/STATIC CIRCUIT BREAKER AND HAD HIGH RESISTANCE ACROSS TERMINALS.  REMOVED CIRCUIT BREAKER AND INSTALLED NEW CIRCUIT BREAKER.- INSTALLED LT CIRCUIT BREAKER PANEL OPS CHECKED GOOD.  WORK DONE IAW MM 24-51-00.

---