# SDR DXTA2012082305102

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 22, 2012
- Submitted: September 17, 2012
- Operation: Air carrier
- Aircraft: [N927QS](https://openairdocs.org/aircraft/N927QS), registered now
- Make and model: Cessna 750
- Registry model: [Cessna 750](https://openairdocs.org/model/cessna-750) (OpenAirDocs)
- Aircraft serial: 7500290
- Aircraft time: 3,515 hours, 2,099 cycles
- Engine: Rroyce AE3007C1
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Relay
- Part number: 1060291
- Part serial: 2980607
- Condition: Burned
- Location: Galley
- Part time: 736 hours, 431 cycles
- Stage of operation: TX
- How discovered: O
- Nature of condition: B, J
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA2012082305102

## Discrepancy

ON MASTER CABIN CONTROL PANEL ON GALLEY NOTICED "FAULT" LIGHT ON RT LIQUID.  REMOVED GALLEY DRAWER TO ACCESS CIRCUIT BREAKERS FOR GALLEY LIQUIDS AND DETECTED A BURNING ELECTRICAL ODOR.  REMOVED WORN OUT SOLID STATE RELAY.   INSTALLED NEW RELAY AND OPS CHECKED GOOD IAW MM 25-30-2.

---