# SDR DXTA2019112213108

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 21, 2019
- Submitted: November 22, 2019
- Operation: Air carrier
- Aircraft: [N209QS](https://openairdocs.org/aircraft/N209QS), registered now
- Make and model: Cndair CL6002B16
- Aircraft serial: 6057
- Aircraft time: 3,755 hours, 2,125 cycles
- System (JASC): [2530 · Buffet/Galleys](https://openairdocs.org/jasc/2530)
- Part: Fan
- Part number: FFB0924EHET500
- Condition: Defective
- Location: Chiller
- Stage of operation: NR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA2019112213108

## Discrepancy

GALLEY FOOD CHILLER STARTED MAKING A GROWLING VIBRATION NOISE AND INCREASED IN INTENSITY OVER TIME WITH A SLIGHT ODER. CHILLER WAS TURNED OFF VIA CABIN CONTROL PANEL PUT THE GROWLING VIBRATION NOISE CONTINUED. THE COCKPIT AC/DC UTILITY WAS DISCONNECTED AND THE NOISE STOPPED AND SLIGHT ODER QUICKLY DISSIPATED. NO FURTHER ISSUES DEVELOPED. // SIGNOFF // PERFORMED T/SHOOTING FOUND GALLEY CHILLER FAN WITH TWO BROKEN BLADES CAUSING VIBRATION NOISE. REMOVED AND REPLACED GALLEY FOOD CHILLER FAN. PERFORMED OPERATIONAL TEST OF CHILLER, ALL OPERATIONAL TEST OK AND NO ODOR
NOTED IAW CL650 SMM25-30-09

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.