# SDR DXTA2026021606896

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 13, 2026
- Submitted: February 16, 2026
- Operation: Air carrier
- Aircraft: [N910QS](https://openairdocs.org/aircraft/N910QS), registered now
- Make and model: Cessna 680A
- Registry model: [Cessna 680A](https://openairdocs.org/model/cessna-680a) (OpenAirDocs)
- Aircraft serial: 680A0324
- Aircraft time: 3,638 hours, 2,387 cycles
- System (JASC): [2121 · Air Distribution Fan](https://openairdocs.org/jasc/2121)
- Part: Blower
- Part number: 99148261
- Part serial: 00546
- Condition: Odor
- Location: Zone 100
- Stage of operation: CR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA2026021606896

## Discrepancy

AT FL430 WE BEGAN TO GET A STRONG ELECTRICAL FUME ODOR.  THE ODOR GOT PROGRESSIVELY WORSE, EXECUTED SMOKE, FIRE PERFUME QRC AND LANDED AS SOON AS PRACTICAL. WAS UNABLE TO LOCATE WHERE THE SMELL WAS EMANATING FROM.  REMOVED RECIRC BLOWER  AND INSTALLED CUSTOMER SUPPLIED OVERHAULED RECIRCULATION BLOWER. COMPLIED WITH SATISFACTORY OPS CHECKS AND LEAK CHECKS OF THE RECIRCULATION BLOWER. REF MM 21-21-15 REMOVED ACM. INSTALLED CUSTOMER SUPPLIED OVERHAULED ACM.OPS CHECKS GOOD. DONE IN REF TO OPERATION AND MAINTENANCE MANUAL 67000108-1.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.