# SDR DXTA2026082009338

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 18, 2026
- Submitted: August 20, 2026
- Operation: Air carrier
- Aircraft: [N158QS](https://openairdocs.org/aircraft/N158QS), registered now
- Make and model: Bombdr BD7001A10
- Aircraft serial: 60024
- Aircraft time: 5,956 hours, 2,093 cycles
- System (JASC): [2820 · Aircraft Fuel Distribution System](https://openairdocs.org/jasc/2820)
- Part: Warning Light
- Condition: False Activation
- Location: Zone 100
- Stage of operation: TO
- How discovered: O
- Nature of condition: N
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTA2026082009338

## Discrepancy

ON TAKEOFF APPROXIMATELY 70KTS CENTER FUEL TRANSFER FAIL AMBER CAS MESSAGE ILLUMINATED. TAKEOFF ABORTED.  PERFORMED OPERATIONAL TEST OF THE CENTER TRANSFER PUMPS IAW AMM 28-22-00. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.

---