# SDR DXTAT2PL6D005EAU5

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 29, 2017
- Submitted: October 2, 2017
- Operation: Air carrier
- Aircraft: [N371QS](https://openairdocs.org/aircraft/N371QS), registered now
- Make and model: Emb EMB-505
- Registry model: [EMB EMB-505](https://openairdocs.org/model/embraer-executive-emb-505) (OpenAirDocs)
- Aircraft serial: 50500279
- Aircraft time: 2,004 hours, 1,580 cycles
- System (JASC): [3620 · Pneumatic Indicating System](https://openairdocs.org/jasc/3620)
- Part: Sensor
- Part number: 130045010
- Part serial: 2871
- Condition: Defective
- Location: Duct Temp
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/DXTAT2PL6D005EAU5

## Discrepancy

AT 36000FT.  DUCT 2 OVERHEAT.  FOLLOWED CHECKLIST.  DUCT ONE OVERHEAT SHORTLY AFTER.   INSTALLED A NEW NR 1 DUCT TEMPERATURE SENSOR AND NEW ECS TEMPERATURE CONTROLLER IAW MM 21-61-03 AND  MM 21-61-01.  OPS CHECKS PERFORMED MM 21-61-00-710-801A/500.  OPS CHECKED GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.