# SDR F3LA200700237

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 12, 2007
- Submitted: September 19, 2007
- Operation: Air carrier
- Aircraft: N921FR
- Make and model: Airbus A319-111
- Registry model: [Airbus A319-111](https://openairdocs.org/model/airbus-a319-111) (OpenAirDocs)
- Aircraft serial: 2010
- Aircraft time: 14,342 hours, 6,889 cycles
- System (JASC): [5321 · Fuselage Floor Panel](https://openairdocs.org/jasc/5321)
- Part: Floorboard
- Part number: D5367180500500
- Condition: Corroded
- Location: Cabin
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/F3LA200700237

## Discrepancy

DURING C-3 CHECK, INSPECTION REPORTED SEVERAL AREAS OF CORROSION ON FLOORBOARD PANEL 163FF.  REPLACED FLOORBOARD PANEL IAW AMM 53-42-12, PB401.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.