# SDR F3LA2009022700036

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 25, 2009
- Submitted: February 27, 2009
- Operation: Air carrier
- Aircraft: N923FR
- Make and model: Airbus A319-111
- Registry model: [Airbus A319-111](https://openairdocs.org/model/airbus-a319-111) (OpenAirDocs)
- Aircraft serial: 2019
- Aircraft time: 19,157 hours, 9,275 cycles
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Power Supply
- Part number: 32145410
- Part serial: 5961
- Condition: Failed
- Location: Emergency Lights
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/F3LA2009022700036

## Discrepancy

MULTIPLE EMERGENCY ESCAPE PATH LIGHTS WERE ILLUMINATED WITH THE EMERGENCY EXIT LIGHT SWITCH IN THE ARM POSITION.  MAINTENANCE INSPECTED OVERHEAD AFT GALLEY BETWEEN THE L2 AND R2 DOORS AND FOUND INSULATION BLANKETS WET (CONDENSATION) CAUSING EMERGENCY LIGHTS TO COME ON INTERMITTENTLY.  MAINTENANCE DRIED AND REPAIRED BLANKETS IAW AMM 25-80-00 PB 801 AND PERFORMED OPERATIONAL CHECK IAW AMM 33-51-00 PB 501.  EMERGENCY POWER LIGHTING IN AFT CABIN STAYS ON WHEN THE EMERGENCY EXIT LIGHT SWITCH IS IN THE ARMED POSITION.  MAINTENANCE REMOVED AND REPLACED THE EMERGENCY POWER SUPPLY UNIT AT 13WL AND PERFORMED OPERATIONAL TEST PER AMM 33-57-38 PB 401.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.