# SDR FDEA200909163308

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 16, 2009
- Submitted: September 21, 2009
- Operation: Air carrier
- Aircraft: [N318FE](https://openairdocs.org/aircraft/N318FE), registered now
- Make and model: Doug DC-10-30F
- Registry model: [Doug DC-10-30F](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30f) (OpenAirDocs)
- Aircraft serial: 46837
- Aircraft time: 81,926 hours, 22,360 cycles
- Engine: Ge CF650C2
- System (JASC): [7323 · Turbine Governor](https://openairdocs.org/jasc/7323)
- Part: Sensor
- Part number: 8901224
- Part serial: WYG40809
- Condition: Malfunctioned
- Location: Nr 1 Engine
- Stage of operation: TO
- How discovered: O
- Nature of condition: J
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/FDEA200909163308

## Discrepancy

DURING T-OFF, WHILE SETTING POWER TARGET 114.4  WHEN N1 REACHED APPROX 98-99 PERCENT (70KTS) N2  EXCEEDENCE ON NR 01 ENGINE, RESET T-OFF AT 70KTS AMBER  ENG 1 EXCEDENCE DISPLAYING, AMBER 109,9 N2 DISPLAYED VCP R  NO RESTRICTION REF: 72-00-00-6 1,  NR 1 ENGINE, N2 EXCEEDENCE 109.9 REQUIRES BOROSCOPE  WITHIN 10 FLIGHT CYCLES REF AMM 72-00-00-6  IAW AMM 72-00-00-6-1 INSPECTED NR 01 ENG INTAKE/EXHAUST.  NO DAMAGED FOUND A/C OK FOR 10 CYCLES.  VCP R OIL REFERENCE: 72-00-00-6 1  TERMINATING  ACTION REQUIRED AT OR BEFORE:  SPEC: 10 CYCLES, EXPIRATION: 22,370 CYCLES.  C/W BORESCOPE INSP IAW MM 72-00-00-6 FOUND ONE BLADE NICKED AND TORN THAT NEEDS BLENDED ON THE NR 1  STAGE OF THE HPC.  BLADE IS MARKED WITH A (NR 27) ON IT FOR  REF. NO OTHER DAMAGED NOTED MM 72-36-00-2.  REMOVED AND REPLACED CIT SENSOR IAW AMM 73-20-02-2 AND CORE SPEED SENSOR IAW AMM 77-12-01-2, CKD OK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.