# SDR FDEA201002010305

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 1, 2010
- Submitted: February 3, 2010
- Operation: Air carrier
- Aircraft: N527FE
- Make and model: Doug MD-11F
- Registry model: [Doug MD-11F](https://openairdocs.org/model/mcdonnell-douglas-md-11f) (OpenAirDocs)
- Aircraft serial: 48601
- Aircraft time: 44,382 hours, 7,373 cycles
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Idg
- Part number: 750875
- Part serial: 0415
- Condition: Failed
- Location: Nr 2
- Part time: 11,127 hours, 2,538 cycles
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/FDEA201002010305

## Discrepancy

T/O 30 MIN DURING CRUISE AT FL 340 GOT "GEN  DRIVE 2 FAULT" QRH DRIVES TO DISC IDG. DISC IDG NR 2.  COMPLIED WITH AMM 24-21-00-2. RESET NR 2 IDG RESET RING.  RAN ALL ENGINES.  NO DISCREPENCIES NOTED.  ACFT ELECTIRIC SYS FUNCTION NORMAL.   SERVICED NR 2 IDG REPLACED GCU PRECAUTIONARY.  RAN ENG IAW JRH, ALL INDICATIONS NORMAL.  AFTER REVIEWING PDIS INDICATING "GEN DRIVE 2 FAULT" AND EPCU FAULT REVIEW FAULTING IDG-2/CV/INTFC AND OIL TEMP HIGH, T/S IAW FIM 24-20-33. FIM REQUIRES IDG REPLACEMENT. R & R NR 2 IDG IAW AMM 24-21-02-4 2. RAN ALL ENGINES IAW JRH, ALL ELECTRICAL SYS TESTED GOOD. NO DISCREPENCIES NOTED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.