## Discrepancy

AFTER TAKE OFF, RECEIVED A NR 3 PACK FLOW DISAGREE.  AIR SYS WAS IN AUTO.  SOON AFTER,  RECEIVED A NR 2 AIR SYS, AIR  SYS 1 OFF & AVIONICS FAN OVERRIDE.  BLEED 1 & 2 WERE  BOTH CLOSED.  SWITCHED CONTROLLERS, BACK TO AUTO, PROBLEM REAPPEARED.  LEAVING NR 3 BLEED ONLY.  ON START HAD A PROBLEM WITH STARTING & AFTER CONFERRING WITH MOCC CYCLED THE CONTROLLER & THAT SEEMED TO FIX IT.  REMOVED AND REPLACED NR 3 FLOW CONTROL VALVE IAW AMM 21-51-01.

---