# SDR FDEA201407241944

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 24, 2014
- Submitted: July 24, 2014
- Operation: Air carrier
- Aircraft: [N684FE](https://openairdocs.org/aircraft/N684FE), registered now
- Make and model: Airbus A300 F4-605R
- Registry model: [Airbus A300 F4-605R](https://openairdocs.org/model/airbus-industrie-a300-f4-605r) (OpenAirDocs)
- Aircraft serial: 802
- Aircraft time: 22,068 hours, 12,210 cycles
- System (JASC): [2934 · Hydraulic Quantity Sensor](https://openairdocs.org/jasc/2934)
- Part: Transmitter
- Part number: 647520201
- Part serial: 7475
- Condition: Faulty
- Location: Hydraulic Sys
- Stage of operation: DE
- How discovered: O
- Nature of condition: N
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/FDEA201407241944

## Discrepancy

IN DESCENT HAD ECAM & OVERHEAD SHOWED LOSS OF FLUID & LOSS OF PRESS IN GREEN SYS.  COMPLIED WITH ECAM FOR LOSS OF PRESS IN GREEN SYS.  FULLY CONFIGURED FOR LANDING HYD FLUID LEVEL INDICATION CAME BACK TO NORMAL, LANDED UNEVENTFUL.  R & R GREEN SYS RESERVOIR TRANSMITTER, NEEDS LEAK CHECK.  R & R GREEN SYS MANIFOLD HYD FILTERS & BOWLS FOR GREEN BRAKE & HYD ELEC PRESS, WILL NEED LEAK CHECK.  INSPECTED HYD SYS, NO DEFECTS NOTED.  RAN BOTH ENGS IAW JRH & LEAK OPERATIONS CHECKED GOOD.  ACFT OK FOR SERVICE.

---