- Page: https://openairdocs.org/sdr/FDEA202104090863

## Discrepancy

PDIS  688     00-00  3337     09APR21  MEM  OPEN  U  CLIMBING THROUGH APPROXIMATELY FL280, 12 MINUTES  INTO FLIGHT, BOTH CENTER TANK FUEL BOOST PUMPS  FAULTED SIMULTANEOUSLY. FOLLOWED ECAM / QRH, PULLED  AND RESET CB M55 ON 132 VU. PUMPS WERE INITIALLY  RECOVERED, THEN FAILED SIMULTANEOUSLY AGAIN  APPROXIMATELY 2 MINUTES LATER. AIR TURN BACK TO  KMEM. NO EMERGENCY DECLARED. REPLACED THE FUEL LEVEL SENSOR 697QJ REF AMM 28-46-21-04 AND TESTED   NORMAL

---