## Discrepancy

AVIONICS SMOKE CLIMBING THROUGH 13000.  SNIFFER FAN  REVEALED NO SMOKE.  RETUNED MEM.  SMOKE WARNING  CLEARED APPROACHING BLOCKS, BUT THEN WARNING  RETURNED AFTER A MINUTE.  UPON SHUTDOWN AND OPENING  COCKPIT DOOR WE SMELLED SMOKE IN CABIN.  REMOVED AND REPLACED SMOKE DETECTOR 13WA IAW AMM 26-15-12-04.  RAN ENGINES PER JRH NO AVIONICS SMOKE LIGHT ILLUMINATED.  WATER ACCUMULATION CHECK COMPLIED WITH IAW AMM 05-50-01-00.  ACFT OK FOR SERVICE.

---