- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 13, 2026
- Submitted: August 14, 2026
- Operation: General aviation
- Aircraft: [N2652](https://openairdocs.org/aircraft/N2652), registered now
- Make and model: Amd FALCON2000EX
- Aircraft serial: 414
- Aircraft time: 523 hours, 336 cycles
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Feeder Cable
- Part number: F2MB691011001E2
- Condition: Melted
- Location: Zone 400
- Part time: 523 hours
- Stage of operation: CL
- How discovered: V
- Nature of condition: J, H, M
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/FE6R202608130001

## Discrepancy

PILOTS REPORTED GENERATOR NO.1 FAIL IN FLIGHT APPROXIMATELY 10 MINUTES AFTER TAKEOFF AND RETURNED TO THE FIELD, UNEVENTFUL LANDING. NO.1 ENGINE DRIVEN GENERATOR FEEDER CABLE PASS-THROUGH IN LH PYLON WAS FOUND MELTED. DAMAGE FOUND ON POSITIVE AND NEGATIVE FEEDER CABLES ON BOTH THE ENGINE SIDE AND AIRFRAME SIDE CABLE RUNS. THE ENTIRE GENERATOR CABLE ASSEMBLY FROM THE LH POWER DISTRIBUTION BOX TO THE NO. 1 GENERATOR REQUIRES REPLACEMENT. PERFORMED CONDUCTIVITY SIGMA TEST OF SURROUNDING PYLON STRUCTURE FOR HEAT DAMAGE, FOUND THE TERMINAL MOUNTING PLATE AND SHUNT ANGLE TO BE OUTSIDE THE EXPECTED CONDUCTIVITY RANGE PROVIDED BY THE OEM.

---