# SDR G1IA20240824065

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 24, 2024
- Submitted: September 6, 2024
- Operation: Air carrier
- Aircraft: [N991GF](https://openairdocs.org/aircraft/N991GF), registered now
- Make and model: Beech C90A
- Registry model: [Beech C90A](https://openairdocs.org/model/beech-c90a) (OpenAirDocs)
- Aircraft serial: 458
- Aircraft time: 6,530 hours, 6,344 cycles
- System (JASC): [2497 · Electrical Power System Wiring](https://openairdocs.org/jasc/2497)
- Part: Diode
- Part number: 9714231880
- Condition: Failed
- Location: Terminal Block
- Stage of operation: AP
- How discovered: O
- Nature of condition: G
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/G1IA20240824065

## Discrepancy

DURING APPROACH, A DUAL GEN FAILURE OCCURRED, WITH NEGATIVE RESULTS TO RESTORE POWER FOLLOWING ESTABLISHED PROCEDURE THROUGH ELECTRONIC CHECKLIST PROVIDED ON EFB. INITIALLY, POWER WAS RESTORED TO GEN 2 FOR ABOUT 15 SECS, BUT RETURNED TO A FAILED STATE.  DECISION MADE TO SHED POWER, BEGAN PUTTING GEAR DOWN & LOCKED. CONTINUED APPROACH TO LANDING PHASE.  LANDING WITHOUT INCIDENT. APPROACH CONDUCTED IN IMC CONDITIONS.  R & R TERMINAL BLOCK TB123-01 DUE TO FAULTED DIODE WITH NEW IAW WDM 32-60-10. PERFOMED GEN BUSS TIE CHECK IAW AMM 12-A-71-00-00-00A-903E-A OPS CHKD GOOD. R & R GEN 2 BUS TIE  WITH SERVICABLE UNIT IAW WDM 24-30-30. GENERATOR CHECK GOOD IAW 12-A-71-00-00-00A-903EA. OPS CHECK FLIGHT SATISFACTORY.

---