# SDR G6OA047

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 26, 2000
- Submitted: August 8, 2000
- Operation: Air carrier
- Aircraft: N607GC
- Make and model: Doug DC-10-30F
- Registry model: [Doug DC-10-30F](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30f) (OpenAirDocs)
- Aircraft serial: 46978
- System (JASC): [3310 · Flight Compartment Lighting](https://openairdocs.org/jasc/3310)
- Part: Harness
- Part number: 2641
- Condition: Arced
- Location: Light Control
- Part time: 62,303 hours
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/G6OA047

## Discrepancy

WHILE TROUBLESHOOTING MEL CONTROL NR M607-4435 FOUND WIRE BUNDLE TO FE PANEL LIGHT CONTROL PANEL BETWEEN P1-299 AND R5-299 CHAFED THROUGH CAUSING ELECTRICAL ARCING ON OUTFLOW VALVE CABLE.  REPAIRED WIRES L3850C22 AND L725B22 PER MM 20-30-13.  OPERATIONAL CHECKS OK.  (M)

---