# SDR HAL95020

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 19, 1995
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: N679HA
- Make and model: Doug DC-9-51
- Registry model: [Doug DC-9-51](https://openairdocs.org/model/mcdonnell-douglas-dc-9-51) (OpenAirDocs)
- Aircraft serial: 47662
- System (JASC): [2170 · Humidity Control System](https://openairdocs.org/jasc/2170)
- Part: Water Separator
- Part number: 17946081
- Condition: Failed
- Location: Aft Fuselage
- Stage of operation: TX
- Nature of condition: B
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HAL95020

## Discrepancy

HNL - FLT 504 - WITH THE LEFT PACK ON, THE CABIN FILLED WITH SMOKE.  IN AUTO MODE DUCT TEMP WENT TO MAXIMUM HOT.  PACK DID NOT SHUT DOWN.  REPLACED THE LEFT AND RIGHT WATER SEPARATORS.  LEAK CHECK IN SERVICE OK.  REPLACED THE LEFT TURBINE COOLING ASSY, LEAK CHECK AND OPS CHECK OK.  REMOVED AND REPLACED THE RT TURBINE COOLING ASSY.  THE LEAK CHECK AND OPS CHECK OK.  RAN PACKS FOR 20 MINUTES WITH APU AND 15 MINUTES WITH ENGINE AND NO SMOKE.  REFERENCE 95ZZZZ157, 158, 159.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.