# SDR HALA0000114

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 6, 2000
- Submitted: May 25, 2000
- Operation: Air carrier
- Aircraft: N128AA
- Make and model: Doug DC-10-10
- Registry model: [Doug DC-10-10](https://openairdocs.org/model/mcdonnell-douglas-dc-10-10) (OpenAirDocs)
- Aircraft serial: 46984
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Shutoff Valve
- Condition: Leaking
- Location: Hydraulic Sys
- Stage of operation: CL
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HALA0000114

## Discrepancy

HNL - FLT 6 - HYD SYSTEM 3 ELEV OFF LIGHT CAME ON DURING CLIMB-OUT.  A/C DIVERTED TO HNL, WHERE AN UNEVENTFUL LANDING WAS MADE.  FOUND 3-2 NON REVERSIBLE SHUTOFF VALVE LEAKING.  REMOVED AND REPLACED SHUTOFF VALVE.  RESERVICED HYD RES BLED SYSTEM.  SHUT OFF VALVE, OPS CHECK OK.  (M)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.