# SDR HALA2008111700854

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 17, 2008
- Submitted: November 18, 2008
- Operation: Air carrier
- Aircraft: [N583HA](https://openairdocs.org/aircraft/N583HA), registered now
- Make and model: Boeing 767-33A
- Registry model: [Boeing 767-33A](https://openairdocs.org/model/boeing-767-33a) (OpenAirDocs)
- Aircraft serial: 25531
- Aircraft time: 72,986 hours, 13,315 cycles
- System (JASC): [2997 · Hydraulic Power System Wiring](https://openairdocs.org/jasc/2997)
- Part: Connector
- Condition: Loose
- Location: Hyd Pump
- Stage of operation: TX
- How discovered: O
- Nature of condition: N
- Precautionary procedure: B
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HALA2008111700854

## Discrepancy

ETOPS SIGNIFICANT SYSTEM, RT HYD PRIME PUMP ANNUNCIATED ON EICAS ASSOC SWITCHED LIGHT (PRESS) ILLUMINATED BTB.  C/W FIM 29-11-00, SECURED RT ENG HYD PUMP CONNECTOR D10980, OPERATED RT ENG PER MM 71-00-00, R ENG PRIMARY PRESS LIGHT EXTINGUISHED, NO MESSAGE ON EICAS, SYSTEM PRESS NORMAL, NO LEAKS ON RT ENG PUMP NOTED.  NO OTHER DEFECTS NOTED, OK FOR SVC.

---