# SDR HALA2009070700282

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 7, 2009
- Submitted: July 8, 2009
- Operation: Air carrier
- Aircraft: [N583HA](https://openairdocs.org/aircraft/N583HA), registered now
- Make and model: Boeing 767-33A
- Registry model: [Boeing 767-33A](https://openairdocs.org/model/boeing-767-33a) (OpenAirDocs)
- Aircraft serial: 25531
- Aircraft time: 75,321 hours, 13,705 cycles
- System (JASC): [2160 · Cabin Temperature Control System](https://openairdocs.org/jasc/2160)
- Part: Sensor
- Part number: 6240141
- Part serial: 7C2396
- Condition: Faulty
- Location: A/C Pack Temp
- Part time: 9,381 hours, 1,868 cycles
- Stage of operation: NR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HALA2009070700282

## Discrepancy

ETOPS SIGNIFICANT SYS - RT PACK TEMP / R PACK OFF LIGHT ILLUMINATED, FOLLOWED QRH, RESET LIGHTS (EICAS) CAME BACK ON AFTER APPROX 8 MINS.  BITE CK  RT PNEUMATIC CONTROLLER FOUND RT PACK TEMP SENSOR FAULT.  REPLACED RT PACK 
TEMP SENSOR IAW AMM 21-51-08.  OPS CK GOOD NO FAULTS.

---