# SDR HALA2010062400275

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 24, 2010
- Submitted: June 25, 2010
- Operation: Air carrier
- Aircraft: N587HA
- Make and model: Boeing 767-33A
- Registry model: [Boeing 767-33A](https://openairdocs.org/model/boeing-767-33a) (OpenAirDocs)
- Aircraft serial: 33421
- Aircraft time: 29,160 hours, 5,557 cycles
- System (JASC): [2160 · Cabin Temperature Control System](https://openairdocs.org/jasc/2160)
- Part: Bulb
- Condition: Failed
- Location: Lt Pack Temp
- Stage of operation: CR
- How discovered: O
- Nature of condition: N
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HALA2010062400275

## Discrepancy

ETOPS SIGNIFICANT SYS - INFO TO MX- LT PACK OUT TEMP IS 275 DEGREES W/ TEMP CONTROL VALVE FULL COLD AND RAM IN DOOR FULL OPEN. DUCT TEMPS NORMAL AND NO OTHER INDICATIONS DISPLAYED.  T/S IAW FIM 21-51-00.  FOUND BAD TEMP BULB. R & R LT PACK OUTLET TEMP BULB IAW AMM 21-52-06.  ALL OPS CK NORMAL.

---