# SDR HALA2020073100162

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 30, 2020
- Submitted: July 31, 2020
- Operation: Air carrier
- Aircraft: [N384HA](https://openairdocs.org/aircraft/N384HA), registered now
- Make and model: Airbus A330-243
- Registry model: [Airbus A330-243](https://openairdocs.org/model/airbus-a330-243) (OpenAirDocs)
- Aircraft serial: 1259
- Aircraft time: 39,532 hours, 6,106 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Priority Valve
- Condition: Malfunctioned
- Location: Nr 1 Engine
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HALA2020073100162

## Discrepancy

ETOPS SIGNIFICANT SYSTEM,   NR 1 ENGINE BLEED NOT CLOSED.  REPLACED THE NR 1 ENGINE PRV IAW AMM 36-11-52-804-A/ 36-11-52-400-804-A.  OPS CHECK AND LEAK CHECK OK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.