# SDR HALA9900233

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 19, 1999
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N125AA](https://openairdocs.org/aircraft/N125AA), registered now
- Make and model: Doug DC-10-10
- Registry model: [Doug DC-10-10](https://openairdocs.org/model/mcdonnell-douglas-dc-10-10) (OpenAirDocs)
- Aircraft serial: 46525
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Housing
- Condition: Cracked
- Location: Hyd System
- Stage of operation: AP
- Nature of condition: K
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HALA9900233

## Discrepancy

HNL - FLT 939 - HYDRAULIC SYSTEM 3 LEVEL OFF LIGHT ON.  SYSTEM 3 HYDRAULIC QUANTITY ZERO, IT HAPPENED ON FINAL APPROACH AFTER ALL FLAPS OUT.  PUMPS WERE TURNED OFF BEFORE 0.  FOUND TRIM CYL INTERLOCK FUSE HOUSING CRACKED.  REMOVED AND REPLACED FUSE PER MM 32-31-06..  OPS LEAK CHECK OK.  RESERVICED QUANTITIES.  (M)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.