# SDR HEEA111153

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 19, 2006
- Submitted: September 25, 2006
- Operation: Air carrier
- Aircraft: [N309PH](https://openairdocs.org/aircraft/N309PH), registered now
- Make and model: Urocop EC 135 P2
- Registry model: [Urocop EC 135 P2](https://openairdocs.org/model/eurocopter-deutschland-ec-135-p2) (OpenAirDocs)
- Aircraft serial: 0403
- Aircraft time: 424 hours
- Engine: Pwa PW206B
- System (JASC): [7797 · Engine Indicating System Wiring](https://openairdocs.org/jasc/7797)
- Part: Connector
- Condition: Contaminated
- Location: Fadec
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HEEA111153

## Discrepancy

DURING CRUISE FLIGHT, WHILE TRANSPORTING AN INTERFACILITY PATIENT, THE NR 2 FADEC MINOR CAUTION INTERMITTENTLY ILLUMINATED.  DISCONNECTED THE NP, TORQUE, AND PMA CONNECTORS AND THEY WERE ALL WET WITH WATER.  CLEANED AND DRIED THEM OFF AND APPLIED STABILANT 22 TO ALL OF THEM AND THAT FIXED THE PROBLEM.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.