# SDR HNAA2009121500358

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 25, 2009
- Submitted: December 16, 2009
- Operation: Air carrier
- Aircraft: N911HA
- Make and model: Dhav DHC8102
- Aircraft serial: 034
- Aircraft time: 60,687 hours, 68,831 cycles
- System (JASC): [2697 · Fire Protection System Wiring](https://openairdocs.org/jasc/2697)
- Part: Connector
- Condition: Dirty
- Location: Overheat Detect
- Stage of operation: IN
- How discovered: C
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HNAA2009121500358

## Discrepancy

APU FIRE OVERHEAT DETECTOR WORK CARD 26-10-02Q FAILED TO LIGHT TEST LAMP OM FIRE BOTTLE CONNECTOR.  CLEANED CONNECTOR AND RECHECKED WORK CARD 26-10-02Q AND TEST LAMP OPS CHECKED GOOD.  SAFETIED CONNECTOR PLUG.

---