IN FLIGHT, NR 1 SYS LOST HYD PRESSURE. 1/2 QT REMAINED. PRESSURE AT 3000. NR 1 HYD ISOLATION VALVE AND ROLL SPOILER INBD HYD CAUTION LIGHT ILLUMINATED.  INSTALLED TEMP FLEX LINE IAW SP 20.2 FROM PRESSURE PORT OF NR 1 ENGINE DRIVEN HYD PUMP TO FIREWALL.  SERVICE NR 1 HYD SYS IAW 12-10-29.  GROUND RAN ACFT.  OPS AND LEAKED CHECKED GOOD.

---