# SDR HNAA2016061700184

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 16, 2016
- Submitted: June 17, 2016
- Operation: Air carrier
- Aircraft: N336EN
- Make and model: Dhav DHC8311
- Aircraft serial: 336
- Aircraft time: 53,603 hours, 63,259 cycles
- System (JASC): [2437 · DC Indicating System](https://openairdocs.org/jasc/2437)
- Part: Monitor
- Condition: Defective
- Location: Electrical Sys
- Stage of operation: TX
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HNAA2016061700184

## Discrepancy

WHEN APU SHUTS DOWN A NEGATIVE LOAD DISPLAYED.  NO, HAD TO RETURN TO GATE, CX'D AFTER HEA.  RING SUSPECTED CONTACTOR WELDED, LATE ACFT.  VERIFIED APU GEN CONTACTOR IS NOT WELDED.  R & R DC POWER MONITOR IAW -8MM 24-31-05.  OPS CHECK GOOD.  OK FOR SERVICE.

---