# SDR HNAA2018090400210

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 31, 2018
- Submitted: September 4, 2018
- Operation: Air carrier
- Aircraft: N601DW
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145046
- Aircraft time: 46,848 hours, 40,506 cycles
- System (JASC): [3620 · Pneumatic Indicating System](https://openairdocs.org/jasc/3620)
- Part: Warning System
- Condition: False Activation
- Location: Cockpit
- Stage of operation: CL
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/HNAA2018090400210

## Discrepancy

BLEED 1 VALVE CLOSED ADVISORY DISPLAYED AFTER T/O WITH VERY LOW BLEED TEPERATURE. RAN ENGINE 1 ON GROUND AT DIFFERENT THRUST SETTINGS AND PERFORMED ENG BLEED VALVE OPERATIONAL CHECK IAW AMM 36-11-05. NO ISSUES NOTED. OKAY FOR SERVICE.

---